Difference between revisions of "Main Page"
From Adcon Support
(→APRO 6) |
(→News) |
||
Line 48: | Line 48: | ||
the first registration. | the first registration. | ||
− | == News== | + | ==[[News| News ]]== |
− | * [[News|Latest News !! PLEASE SET TO YOUR WATCHLIST !!]] | + | * [[News|Latest News ->->->->->->->->-> !! PLEASE SET TO YOUR WATCHLIST !!]] |
− | * [[News_Archive| | + | * [[News_Archive|News_Archive]] |
== Search / Categories == | == Search / Categories == |
Revision as of 15:49, 24 February 2014
Welcome to the ADCON WIKI for FAQ and HowTo's
What is the Adcon WIKI ?
Welcome to the Adcon Wiki! If you are looking for answers to specific problems, need general technical support, want to get some insider information on Adcon products, need a manual, or just want to browse the FAQ section, then this is the right place to go! Become a registered user. This will offer two distinct advantages: As a registered user you can subscribe to our update service - and you will automatically be informed about any changes, news or updates made to your favourite topics! You will automatically receive our newsletter, bringing to you product information, success stories, background details, and more.
How to register? / Searching ?
Send an email to support@adcon.at and include the following information:
- Your Email Address:
- Alternative Email Address:
- Your User Name (to login to the Online system, eg. John):
- Alternative User Name (if the username is already in use, eg. John1980):
- Your Real Name:
- Your Company Website:
- Where did you learn about the Adcon Wiki?:
- Job description (eg. sales, technical support, developer...):
Whats happens next?
Our support team verifies your information and you will receive a system email which includes the login details within a few hours.
- Forgot your password?
Go to the login page Special:Userlogin and enter your login name and choose E-mail password. A new password will be sent to the email account given at the first registration.
News
Search / Categories
- Search for information on categories: This link shows an direct overview about the pages
- Show all available pages: ALL Pages
Downloads / Latest Releases / Important News
Firmware relase information for all hardware products
Manuals
Remote Support
- DOWNLOAD Download link for the Adcon Remote Support Tool (Teamviewer 7)
- Info for remote support
Adcon Terminology
A comprehensive list with proper explanations can be found here.
- emu3ap
- Emulation software for addVANTAGE 3.45 to allow local and radio communication via a serial or telnet interface. This interface was used for all communication between addVANTAGE and the A730SD receiver. It was also implemented into the A840 Telemetry Gateway for those who wanted to use it with addVANTAGE 3.45 rather than addVANTAGE Pro. It is no longer implemented in the new A850 Telemetry Gateway, and is no longer supported or developed.
- RTU
- Remote Transmission Unit, such as A733, A723, A740. This term refers to both radio (UHF) and GSM/GPRS devices.
- LoS
- Line of Sight. When manufacturers of radios talk about transmission distances, they always refer to unobstructed Line of Sight transmissions. The distances that can actually be achieved vary greatly, depending on lots of circumstances, such as the installation height of the RTU and the receiver, obstacles between the two (trees, mountains, power lines, buildings, ...), atmospheric conditions and others. So please don't take LoS transmission distance for granted for your specific installation!
- DEVID
- Device identifier: this is the serial number of an RTU
- GUI
- Graphical User Interface
- CLI
- Command Line Interface
- SST
- Sensor Supply Time, this is the time a sensor requires to provide a stable output. For most Adcon sensors this is typically 2 seconds or less.
- SLOT
- Averaging Time of the RTU
- POLL
- Request for RTU data
Hardware
RTUs
- General information
- Series 3
- Series 4
- RTU Hardware documentation
- Hybrid Devices
- Outdated / discontinued hardware
- A720 addIT, series 1 & 2
- A730 MD
- A740 addNODE
Gateways / Receivers
- A850 Telemetry Gateway
- A840 Telemetry Gateway
- Discontinued Gateway types (no firmware updates available)
- A720-B LITE Receiver
- A730 SD
- General FAQs about Telemetry Gateway
Sensors
- Custom Sensor Specification
- SDI12 Sensors
- Analog Sensors
- Digital Sensors
- Pulse Counter Sensors
- FAQ's about Sensors
- Sensor maintenance
Accessories
Please visit also our official web page http://www.adcon.at
- Tools
- Adapters
- Field Equipment
- A501 addVALVE
- A510 Data Display
- External Devices for the Adcon Telemetry Gateway
- Wavecom External GSM Modem
- External USB Modem
Software
APRO 6
- APRO6.4
- APRO6.3
- APRO6.2
- General infos about APRO6.x (6.0, 6.1,6.2 ....
- Detailed infos about APRO6.x
- Extension manual 6.x http://www.adcon-support.at/manuals_free/apro6_extensions.pdf
- APRO6.2 Administrator manual[2]
- APRO6.2 User manual [3]
- APRO6 FAQ
APRO 4.3 / 5.0 / 5.1 / 5.3 / 5.4
- General Infos about APRO5
- addVANTAGE Pro 5.4
- addVANTAGE Pro 5.3
- addVANTAGE Pro 5.1
- addVANTAGE Pro 5
- APRO5 Extensions
- addVANTAGE Pro 4.3
Miscellaneous / Outdated Software
- A2A addUPI-to-ASCII
- addVANTAGE 3.46
- OPC Server
- Compatibility Info
- Recommended software tools
- Script File samples for APRO and others
- Tips and Tricks and Know How
- addVANTAGE LITE
- A740 Configurator
Other
Trouble Shooting
- Basics
Miscellaneous / Unsorted
SDI12
RS232
Installation Info and Pictures
- Weather Stations
- ETo Stations
- Water Management (Flow, Level, Quality)
- Various
- Agriculture (Soil Moisture, .....)
- Curious and funny
- Cooooool
APRO Weather Links
INFO | LINK | Type |
---|---|---|
APRO Demo Server LiveData Map | [4] | LiveData Map View / Overview |
APRO Demo Server LiveData List | [5] | LiveData List View / Overview |
Adcon Weather Station Klosterneuburg |
[6] | LiveData Direct Link |
Muckendorf Public Trend | [7] | Public Trend |
Muckendorf LiveData | [8] | LiveData Direct Link |